Transcription

Report No: n of the Responsible Testing Laboratory .3Identification of the Responsible Testing Location .31.3List of Test Equipments .32.TECHNICAL INFORMATION.42.1Applicant Information .42.2Photographs of the EUT .42.3Identification of all used EUT .43.TEST RESULTS .53.1Applied Reference Documents .53.2Test Conditions .53.3Summary of test results .7ANNEX A.PHOTOGRAPHS .8Page 2 of 10

Report No: SZ16040012E01General Information1.1Identification of the Responsible Testing LaboratoryCompany Name:Address:Responsible Test Lab Manager:Telephone:Facsimile:1.2Shenzhen Morlab Communications Technology Co., Ltd.3/F, Electronic Testing Building, Shahe Road, NanshanDistrict, Shenzhen, 518055 P. R. ChinaMr. Shu Luan 86 755 86130228 86 755 86130218Identification of the Responsible Testing LocationName:Address:1.3Shenzhen Morlab Communications Technology Co., Ltd.3/F, Electronic Testing Building, Shahe Road, NanshanDistrict, Shenzhen, 518055 P. R. ChinaList of Test EquipmentsNo123456Type8960-5515C System SimulatorCMU 200 System SimulatorE5071B Vector NetworkAnalyzer4*4*4 Full Anechoic ChamberSG24 Multi-probe AntennaMeasurement SystemSimulated HeadSpecificationManufacturer: AgilentManufacturer: R&SManufacturer: AgilentManufacturer: SatimoManufacturer: SatimoManufacturer:IndexSARPage 3 of 10

Report No: SZ16040012E012.Technical InformationNote: Provide by applicant.2.1Applicant .2Cellsafe PTY.LTDNANANANAPhotographs of the EUTPlease reference annex A.2.3Identification of all used EUTThe EUT Identity consists of numerical and letter characters (see the table below), the first fivenumerical characters indicates the Type of the EUT defined by Morlab, the next letter characterindicates the test sample, and the following two numerical characters indicates the software version ofthe test sample.EUT IdentityEUT01IMEI(n.a.)Hardware Version(n.a.)Software Version(n.a.)Page 4 of 10

Report No: SZ16040012E013.Test Results3.1Applied Reference DocumentsNo1IdentityTest Plan for Mobile StationOver the Air Performance3.2Test Conditions3.2.1Test Environment ConditionsDocument TitleMethod of Measurement for Radiated RF Power andReceiver Performance V2.2.2During the measurement, the environmental conditions were within the listed ranges:Temperature ( C): 20 - 25Relative Humidity (%): 30 - 60Atmospheric Pressure (kPa): 86 - 1063.2.2Measurement UncertaintyThe uncertainty is calculated using the methods suggested in the "Guide to the Expression ofUncertainty in Measurement" (GUM) published by ISO.TRP Uncertainty in Measurement of GSM1800 in Freespace: 1.751dBTRP Uncertainty in Measurement of WCDMA2100 in Freespace: 1.845dBTIS Uncertainty in Measurement of GSM1800 in Freespace: 1.713dBTIS Uncertainty in Measurement of WCDMA2100 in Freespace: 1.799dBPage 5 of 10

Report No: SZ16040012E013.2.3Test SetupPage 6 of 10

Report No: SZ16040012E013.3 Summary of test results For Samsung s73.3.1Total Radiated Power (TRP)TRP(-dBm)BandWCDMAOriginalwith Cellsafe quency3.3.2Total Isotropic Sensitivity (TIS)TIS(-dBm)BandWCDMAFrequencyOriginalwith Cellsafe 2Page 7 of 10

Report No: SZ16040012E013.4 Summary of test results For samsung s7 edge3.4.1Total Radiated Power (TRP)TRP(-dBm)BandWCDMAFrequencyOriginalwith Cellsafe .2Total Isotropic Sensitivity (TIS)TIS(-dBm)BandWCDMAFrequencyOriginalwith Cellsafe 1Page 8 of 10

Report No: SZ16040012E012. Testing environment for samsung s6Page 9 of 10

Report No: SZ16040012E013.Testing environent for samsung s7 edgePage 10 of 10

3.4 Summary of test results For samsung s7 edge 3.4.1Total Radiated Power (TRP) 3.4.2Total Isotropic Sensitivity (TIS) Page 8 of 10 Band Frequency TRP(-dBm) Original withCellsafeChip WCDMA 1950MHz 23.8022 23.0114 897.6MHz 22.3325 21.7883 Band Frequency TIS(-dBm) Original withCellsafeChip W