Transcription

Brocade MIBReference Manual Version 4.1.x4.0.x3.1.x3.0.x2.6.xPublication Number: 53-0000521-02Publication Date: 04/25/03

Copyright 2003, Brocade Communications Systems, Incorporated.ALL RIGHTS RESERVED.Publication Number: 53-0000521-02BROCADE, the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, andSilkWorm Express, are trademarks or registered trademarks of Brocade Communications Systems, Inc. or itssubsidiaries in the United States and/or in other countries. All other brands, products, or service names are or may betrademarks or service marks of, and are used to identify, products or services of their respective owners.FICON is a registered trademark of IBM Corporation in the US and other countries.Notice: The information in this document is provided “AS IS,” without warranty of any kind, including, withoutlimitation, any implied warranty of merchantability, noninfringement or fitness for a particular purpose. Disclosure ofinformation in this material in no way grants a recipient any rights under Brocade's patents, copyrights, trade secrets orother intellectual property rights. Brocade reserves the right to make changes to this document at any time, withoutnotice, and assumes no responsibility for its use.The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entitywith respect to any loss, cost, liability, or damages arising from the information contained in this book or the computerprograms that accompany it.Notice: The product described by this document may contain “open source” software covered by the GNU GeneralPublic License or other open source license agreements. To find-out which open source software is included in Brocadeproducts, view the licensing terms applicable to the open source software, and obtain a copy of the programming sourcecode, please visit http://www.brocade.com/support/oscd.Export of technical data contained in this document may require an export license from the United States Government.

Brocade Communications Systems, IncorporatedCorporate Headquarters1745 Technology DriveSan Jose, CA 95110T: (408) 487-8000F: (408) 487-8101Email: [email protected] HeadquartersShiroyama JT Trust Tower 36th Floor4-3-1 Toranomon, Minato-kuTokyo, Japan 105-6036T: 81 35402 5300F: 81 35402 5399Email: [email protected] Headquarters29, route de l’AeroportCase Postale 105CH-1211 Geneva 15,SwitzerlandT: 41 22 799 56 40F: 41 22 799 56 41Email: [email protected] America Headquarters5201 Blue Lagoon DriveMiami, FL 33126T: (305) 716-4165Email: [email protected]

Document HistoryThe table below lists all versions of the Brocade MIB Reference Manual.Document TitlePublication Number Publication DateBrocade MIB Reference Manual (v2.3)53-0000069-02December 2000Brocade MIB Reference Manual (v3)53-0000134-03July 2001Brocade MIB Reference Manual (v3.0, 4.0)53-0000184-02March 2002Brocade MIB Reference Manual(v4.1, 4.0.x, 3.1, 3.0.x, 2.6.x)53-0000521-02April 2003

ContentsPrefaceSection IChapter 1What’s New in This Book. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiIntended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiiManual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiiiRelated Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiiiHow to Get Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvStandard MIBsMIB-II (RFC1213-MIB)Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1MIB-II Object Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2Textual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5System Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6Interfaces Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8Interfaces Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9Address Translation Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14Address Translation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14IP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15IP Address Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18IP Routing Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19IP Address Translation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23Additional IP Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24ICMP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24TCP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-27TCP Connection Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-29Additional TCP Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31Brocade MIB Referencev

UDP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31UDP Listener Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32EGP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32EGP Neighbor Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33Additional EGP Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36Transmission Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-37SNMP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-37Chapter 2FE MIB ObjectsOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1FIBRE-CHANNEL-FE-MIB (mib-2 branch). . . . . . . . . . . . . . . . . . . . . . . . .2-2FIBRE-CHANNEL-FE-MIB Organization . . . . . . . . . . . . . . . . . . . . . . .2-3Definitions for FIBRE-CHANNEL-FE-MIB . . . . . . . . . . . . . . . . . . . . . .2-6Configuration Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8Status Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13Error Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18Accounting Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20Capability Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25FCFABRIC-ELEMENT-MIB (experimental branch) . . . . . . . . . . . . . . . . . . 2-28Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28FCFABRIC-ELEMENT-MIB Organization . . . . . . . . . . . . . . . . . . . . . . . 2-29Definitions for FCFABRIC-ELEMENT-MIB . . . . . . . . . . . . . . . . . . . . . 2-31Configuration Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34Operation Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39Error Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45Accounting Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47Capability Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47viBrocade MIB Reference

Chapter 3Entity MIB ObjectsOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1Entity MIB System Organization of MIB Objects . . . . . . . . . . . . . . . . . .3-2Definitions for Entity MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4Textual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4Entity MIB Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6Physical Entity Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6Logical Entity Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15Entity Mapping Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17General Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20Entity MIB Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21Entity MIB Conformance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21Section IIChapter 4Brocade Proprietary MIBsSW-MIB ObjectsOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2SW-MIB System Organization of MIB Objects . . . . . . . . . . . . . . . . . . . .4-2Textual Conventions for SW-MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7sw Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10System Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13Flash Administration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17Fabric Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23SW Agent Configuration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27Fibre Channel Port Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28Name Server Database Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34Event Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36Fabric Watch Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38End Device Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47All Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49ASIC Performance Monitoring Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50Trunking Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53Brocade MIB Referencevii

Chapter 5Section IIIChapter 6High Availability MIB ObjectsOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1High Availability Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3FRU Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-4FRU History Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5Control Processor (CP) Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6haMIBTraps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7Fibre Alliance MIBFibre Alliance MIB ObjectsOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1FCMGMT-MIB System Organization of MIB Objects . . . . . . . . . . . . . .6-2Definitions for FCMGMT-MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-5Connectivity Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6Connectivity Unit Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6Connectivity Unit Revisions Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14Connectivity Unit Sensor Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15Connectivity Unit Port Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18Connectivity Unit Event Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-28Connectivity Unit Link Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31Statistics Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-35Service Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-46Connectivity Unit Service Scalars Group. . . . . . . . . . . . . . . . . . . . . . . . . 6-46Connectivity Unit Service Tables Group . . . . . . . . . . . . . . . . . . . . . . . . . 6-46SNMP Trap Registration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-48Revision Number Scalar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-50Unsupported Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-51Related Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-51viiiBrocade MIB Reference

Appendix A MIB Object GroupingsOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1Switch Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1Sensor Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1Port Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-2Event Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-2ISL and End Device Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3SNMP Configuration Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3Series 3000 Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3Appendix B MIB OIDs and Their Matching Object NamesMIB OIDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1IndexBrocade MIB Referenceix

xBrocade MIB Reference

PrefaceThis manual provides comprehensive information to help you administer your SilkWorm switch andstorage area network (SAN). This manual was developed to help technical experts operate, maintain,and troubleshoot SAN products. A list of additional SAN resource reference materials is also included.The sections that follow provide: A summary of updates to this document.The intended audience for this document.Information to help you use Brocade documentation.Information on additional SAN resources.How to get Technical Support.What’s New in This BookThe following changes have been made since this book was last released (part number53-0000184-02): Information that was added:- Each MIB listing now contains the complete Object ID (OID).- The following new Brocade-specific MIBs have been added:- HA-MIB(High Availability enhancements)- Entity-MIBThese MIBs are supported only in Fabric OS v4.1.-Brocade MIB ReferenceSection II includes MIB loading information and a Fabric OS compatibility table.The SW-MIB has been combined into one master MIB.Brocade supports two FE MIBs, one in the experimental branch and one in the mib-2 branch.Both of these MIBs are listed in Chapter 2, FE MIB Objects.For Fabric OS v4.1, the following MIB features are new or updated:- Security Support- Fabric Watch (FW) Support- Field Replaceable Unit (FRU) Supportxi

Information that was modified:- This document has been reorganized into the following sections, with appropriate chapters ineach section:- Standard MIBs- Brocade Proprietary MIBs- Fibre Alliance MIBs- This document now describes the MIBs that are supported in the following Fabric OS versions:- v2.6.x- v3.x- v4.x.- The MIB trees at the beginning of each chapter now contain links to the MIB objects. If anobject is blue, you can click it to jump to the MIB description.- Because this document supports multiple Fabric OS versions, the version number of thedocument no longer corresponds to the version number of the Fabric OS. When Brocade makesany modifications to the Management Information Base (MIB) files, the updated Brocade MIBReference document will accompany the subsequent Fabric OS release and the version numberwill change as follows:- If a new MIB is added:The version number will increment by “1.x.x” (Version 6.0 will become Version 7.0)-If no new MIBs are added, but an existing MIB is modified:The version number will increment by “x.1.x” (Version 7.0 will become Version 7.1).-If this is a new Fabric OS release with no MIB updates:The version number will increment by “x.x.1” (Version 7.1 will become Version 7.1.1). Information that was removed:- The Syntax, Access, and Status entries have been removed from each MIB object. The MIBfiles contain this information.Intended AudienceThis document is intended for use by systems administrators and technicians experienced withnetworking, Fibre Channel, and SAN technologies.xiiBrocade MIB Reference

Manual ConventionsThis section lists text formatting conventions and important notices formats used in this document.FormattingThe following table describes the formatting conventions that are used in this book:ConventionPurposebold text italic textcode textidentifies command namesidentifies GUI elementsidentifies keywords/operandsidentifies text to enter at the GUI or CLIprovides emphasisidentifies variablesidentifies paths and internet addressesidentifies book titles and cross referencesidentifies CLI outputidentifies syntax examplesNotes, Cautions, and WarningsThe following notices appear in this document:Note:A note provides a tip, emphasizes important information, or provides a reference to relatedinformation.Caution:Warning:A caution alerts you to potential damage to hardware, firmware, software, or data.A warning alerts you to potential danger to personnel.Related PublicationsThis section lists additional documentation that you may find helpful.Brocade MIB Referencexiii

Brocade DocumentationThe following related publications are provided on the Brocade Documentation CD-ROM and on theBrocade Partner Web site: Brocade Fabric OS documentation- Brocade Diagnostic and System Error Message Reference- Brocade Fabric OS Procedures Guide- Brocade Fabric OS ReferenceBrocade Fabric OS optional features documentation- Brocade Advanced Performance Monitoring User's Guide- Brocade Advanced Web Tools User's Guide- Brocade Advanced Zoning User's Guide- Brocade Distributed Fabrics User's Guide- Brocade Fabric Watch User’s Guide- Brocade ISL Trunking User's Guide- Brocade QuickLoop User's Guide (v 3.1 only)- Brocade Secure Fabric OS User's Guide- Secure Fabric OS QuickStart GuideBrocade Hardware documentation- Brocade SilkWorm 12000 Hardware Reference (for v.4.1 software)- Brocade SilkWorm 12000 QuickStart Guide (for v4.1 software)- Brocade SilkWorm 3900 Hardware Reference (for v.4.1 software)- Brocade SilkWorm 3800 Hardware Reference (for v.3.1 software)- Brocade SilkWorm 3200 Hardware Reference (for v.3.1 software)Release notes are available on the Brocade Partner Web site and are also bundled with the Fabric OS.Additional Resource InformationFor practical discussions about SAN design, implementation, and maintenance, Building SANs withBrocade Fabric Switches is available through:http://www.amazon.comFor additional Brocade documentation, visit the Brocade SAN Info Center and click on the ResourceLibrary location:http://www.brocade.comFor additional resource information, visit the Technical Committee T11 Web site. This Web siteprovides interface standards for high-performance and mass storage applications for fibre channel,storage management, as well as other applications:http://www.t11.orgFor information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site:http://www.fibrechannel.orgxivBrocade MIB Reference

How to Get Technical SupportContact your switch supplier for hardware, firmware, and software support, including product repairsand part ordering. To assist your support representative and to expedite your call, have the followingthree sets of information immediately available when you call:1.General Information 2.Technical Support contract number, if applicableswitch modelswitch operating system versionerror messages receivedsupportshow command outputdetailed description of the problem and specific questionsdescription of any troubleshooting steps already performed and resultsSwitch Serial NumberThe switch serial number and corresponding bar code are provided on the serial number label, asshown below.:*FT00X0054E9FT00X0054E9The serial number label is located as follows: 3.Worldwide Name (WWN) Brocade MIB ReferenceSilkWorm 2000 series switches: Bottom of chassisSilkWorm 3200 and 3800 switches: Back of chassisSilkWorm 3900 switches: Bottom of chassisSilkWorm 6400 and 12000 switches: Inside front of chassis, on wall to left of portsSilkWorm 3900 and 12000 switches: Provide the license ID. Use the licenseidshow commandto display the license ID.All other SilkWorm switches: Provide the switch WWN. Use the wwn command to display theswitch WWN.xv

xviBrocade MIB Reference

SectionStandard MIBsIThis section provides the following information: Brocade MIB ReferenceChapter 1, MIB-II (RFC1213-MIB)Chapter 2, FE MIB ObjectsChapter 3, Entity MIB ObjectsI-1

I-2Brocade MIB Reference

ChapterMIB-II (RFC1213-MIB)1This chapter provides descriptions and other information specific to MIB-II, including the followinginformation: Overview on page 1-1System Group on page 1-6Interfaces Group on page 1-8Address Translation Group on page 1-14IP Group on page 1-15ICMP Group on page 1-24TCP Group on page 1-27UDP Group on page 1-31EGP Group on page 1-32Transmission Group on page 1-37SNMP Group on page 1-37OverviewThe descriptions of each of the MIB variables in this chapter come directly from the MIB-II itself. Thenotes that follow the descriptions typically pertain to Brocade-specific information and are provided byBrocade.The objects in MIB-II are organized into the following groupings: Brocade MIB ReferenceSystem GroupInterfaces GroupAddress Translation GroupIP GroupICMP GroupTCP GroupUDP GroupEGP GroupTransmission GroupSNMP Group1-1

1MIB-II (RFC1213-MIB)MIB-II Object HierarchyFigure 1-1 through Figure 1-4 depict the organization and structure of MIB-II.- iso (1)- org (3)- dod (6)- internet (1)- directory (1)- mgmt (2)- mib-2 (1)- system (1)- interfaces (2)- at (3)- ip (4)- icmp (5)- tcp (6)- udp (7)- egp (8)- transmission (10)- snmp (11)Figure 1-11-2MIB-II Overall Tree StructureBrocade MIB Reference

MIB-II (RFC1213-MIB)- system (1.3.6.1.2.1.1)l sysDescr (1)l sysObjectID (2)l sysUpTime (3)l sysContact (4)l sysName (5)l sysLocation (6)l sysServices (7)- interfaces (1.3.6.1.2.1.2)l ifNumber (1)r ifTable (2)x ifEntry (1)l ifIndex (1)l ifDescr (2)l ifType (3)l ifMtu (4)l ifSpeed (5)l ifPhysAddress (6)l ifAdminStatus (7)l ifOperStatus (8)l ifLastChange (9)l ifInOctets (10)l ifInUcastPkts (11)l ifInNUcastPkts (12)l ifInDiscards (13)l ifInErrors (14)l ifInUnknownProtos (15)l ifOutOctets (16)l ifOutUcastPkts (17)l ifOutNUcastPkts (18)l ifOutDiscards (19)l ifOutErrors (20)l ifOutQLen (21)l ifSpecific (22)- at (1.3.6.1.2.1.3)r atTable (1)x atEntry (1)l atIfIndex (1)l atPhysAddress (2)l atNetAddress (3)Figure 1-2Brocade MIB Reference1- ip (1.3.6.1.2.1.4)l ipForwarding (1)l ipDefaultTTL (2)l ipInReceives (3)l ipInHdrErrors (4)l ipInAddrErrors (5)l ipForwDatagrams (6)l ipInUnknownProtos (7)l ipInDiscards (8)l ipInDelivers (9)l ipOutRequests (10)l ipOutDiscards (11)l ipOutNoRoutes (12)l ipReasmTimeout (13)l ipReasmReqds (14)l ipReasmOKs (15)l ipReasmFails (16)l ipFragOKs (17)l ipFragFails (18)l ipFragCreates (19)r ipAddrTable (20)x ipAddrEntry (1)l ipAdEntAddr (1)l ipAdEntIfIndex (2)l ipAdEntNetMask (3)l ipAdEntBcastAddr (4)l ipAdEntReasmMaxSize (5)r ipRouteTable (21)x ipRouteEntry (1)l ipRouteDest (1)l ipRouteIfIndex (2)l ipRouteMetric1 (3)l ipRouteMetric2 (4)l ipRouteMetric3 (5)l ipRouteMetric4 (6)l ipRouteNextHop (7)l ipRouteType (8)l ipRouteProto (9)l ipRouteAge (10)l ipRouteMask (11)l ipRouteMetric5 (12)l ipRouteInfo (13)r ipNetToMediaTable (22)x ipNetToMediaEntry (1)l ipNetToMediaIfIndex (1)l ipNetToMediaPhysAddress (2)l ipNetToMediaNetAddress (3)l ipNetToMediaType (4)l ipRoutingDiscards (23)Tree Structure for MIB-II System, Interfaces, AT, and IP Groups1-3

1MIB-II (RFC1213-MIB)- icmp (1.3.6.1.2.1.5)l icmpInMsgs (1)l icmpInErrors (2)l icmpInDestUnreachs (3)l icmpInTimeExcds (4)l icmpInParmProbs (5)l icmpInSrcQuenchs (6)l icmpInRedirects (7)l icmpInEchos (8)l icmpInEchoReps (9)l icmpInTimestamps (10)l icmpInTimestampReps (11)l icmpInAddrMasks (12)l icmpInAddrMaskReps (13)l icmpOutMsgs (14)l icmpOutErrors (15)l icmpOutDestUnreachs (16)l icmpOutTimeExcds (17)l icmpOutParmProbs (18)l icmpOutSrcQuenchs (19)l icmpOutRedirects (20)l icmpOutEchos (21)l icmpOutEchoReps (22)l icmpOutTimestamps (23)l icmpOutTimestampReps (24)l icmpOutAddrMasks (25)l icmpOutAddrMaskReps (26)- tcp (1.3.6.1.2.1.6)l tcpRtoAlgorithm (1)l tcpRtoMin (2)l tcpRtoMax (3)l tcpMaxConn (4)l tcpActiveOpens (5)l tcpPassiveOpens (6)l tcpAttemptFails (7)l tcpEstabResets (8)l tcpCurrEstab (9)l tcpInSegs (10)l tcpOutSegs (11)l tcpRetransSegs (12)r tcpConnTable (13)x tcpConnEntry (1)l tcpConnState (1)l tcpConnLocalAddress (2)l tcpConnLocalPort (3)l tcpConnRemAddress (4)l tcpConnRemPort (5)l tcpInErrs (14)l tcpOutRsts (15)Figure 1-31-4- udp (1.3.6.1.2.1.7)l udpInDatagrams (1)l udpNoPorts (2)l udpInErrors (3)l udpOutDatagrams (4)r udpTable (5)x udpEntry (1)l udpLocalAddress (1)l udpLocalPort (2)- egp (1.3.6.1.2.1.8)l egpInMsgs (1)l egpInErrors (2)l egpOutMsgs (3)l egpOutErrors (4)r egpNeighTable (5)x egpNeighEntry (1)l egpNeighState (1)l egpNeighAddr (2)l egpNeighAs (3)l egpNeighInMsgs (4)l egpNeighInErrs (5)l egpNeighOutMsgs (6)l egpNeighOutErrs (7)l egpNeighInErrMsgs (8)l egpNeighOutErrMsgs (9)l egpNeighStateUps (10)l egpNeighStateDowns (11)l egpNeighIntervalHello (12)l egpNeighIntervalPoll (13)l egpNeighMode (14)l egpNeighEventTrigger (15)l egpAs (6)Tree Structure for MIB-II ICMP, TCP, UDP, and EGP GroupsBrocade MIB Reference

MIB-II (RFC1213-MIB)1- snmp (1.3.6.1.2.1.11)l snmpInPkts (1)l snmpOutPkts (2)l snmpInBadVersions (3)l snmpInBadCommunityNames (4)l snmpInBadCommunityUses (5)l snmpInASNParseErrs (6)l snmpInTooBigs (8)l snmpInNoSuchNames (9)l snmpInBadValues (10)l snmpInReadOnlys (11)l snmpInGenErrs (12)l snmpInTotalReqVars (13)l snmpInTotalSetVars (14)l snmpInGetRequests (15)l snmpInGetNexts (16)l snmpInSetRequests (17)l snmpInGetResponses (18)l snmpInTraps (19)l snmpOutTooBigs (20)l snmpOutNoSuchNames (21)l snmpOutBadValues (22)l snmpOutGenErrs (24)l snmpOutGetRequests (25)l snmpOutGetNexts (26)l snmpOutSetRequests (27)l snmpOutGetResponses (28)l snmpOutTraps (29)l snmpEnableAuthenTraps (30)Figure 1-4Tree Structure for MIB-II SNMP GroupTextual ConventionsTable 1-1 lists the textual conventions used for MIB-II.Table 1-1Brocade MIB ReferenceMIB-II Textual ConventionsType DefinitionValueDisplayStringOctet String of size 0 to 255PhysAddressOctet String1-5

1MIB-II (RFC1213-MIB)ImportsThe following objects and types are imported from RFC1155-SMI: stem GroupImplementation of the System Group is mandatory for all systems. If an agent is not configured to have avalue for any of the System Group variables, a string of length 0 is returned.sysDescrOID1.3.6.1.2.1.1.1DescriptionA textual description of the entity.Note:This value should include the full name and version identification of the hardware type, softwareoperating system, and networking software. This must contain only printable ASCII characters.Default Value Fibre Channel Switch. Set this value using the agtcfgSet telnet e vendor’s authoritative identification of the network management subsystemcontained in the entity.Note:This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy andunambiguous means for determining what kind of box is being managed.Example:If vendor “Flintstones, Inc.” was assigned the subtree 1.3.6.1.4.1.4242, it could assign theidentifier 1.3.6.1.4.1.4242.1.1 to its “Fred Router”.Default value Dev.fibrechannel.fcSwitch.sw1-6Brocade MIB Reference

MIB-II onThe time (in hundredths of a second) since the network management portion of thesystem was last tionThe textual identification of the contact person for this managed node, together withinformation on how to contact this person.Note:Default value Field Support. Set this value using the agtcfgSet telnet command.sysNameOID1.3.6.1.2.1.1.5DescriptionAn administratively-assigned name for this managed node. By convention, this is thenode’s fully-qualified domain name.Note:Default value preassigned name of the switch.sysLocationOID1.3.6.1

The table below lists all versions of the Brocade MIB Reference Manual. Document Title Publication Number Publication Date Brocade MIB Reference Manual (v2.3) 53-0000069-02 December 2000 Brocade MIB Reference Manual (v3) 53-0000134-03 July 2001 Brocade MIB Reference Manual (v3.0, 4.0) 53-0000184-02