KODAK PROFESSIONAL T-MAX DevelopersDecember 2017 J-86TECHNICAL DATA / CHEMICALSKODAK PROFESSIONAL T-MAX Developer is amoderately active, liquid black-and-white film developerthat offers enhanced shadow detail in normally processedand push-processed films. The same description applies toKODAK PROFESSIONAL T-MAX RS Developer andReplenisher except that it is a black-and-white filmdeveloper and replenisher. Like T-MAX Developer, T-MAXRS Developer and Replenishler produces higher imagequality (enhanced shadow detail) than currentpush-processing developers when you process filmnormally or push it one, two, or three stops.You can use T-MAX Developer to process roll sizes ofKODAK PROFESSIONAL T-MAX Films and most otherblack-and-white continuous-tone films. Do not use thisdeveloper to process sheet film. You can use T-MAX RSDeveloper and Replenisher to process all roll and sheetsizes of KODAK PROFESSIONAL T-MAX Films, as well asmost other black-and-white continuous-tone films.T-MAX Developer is intended for use in unreplenishedsystems. For replenished systems, use T-MAX RSDeveloper and Replenisher. T-MAX RS Developer andReplenisher is a hydroquinone-based, two-part developerspecially formulated for replenished systems, but you canalso use it in unreplenished systems.T-MAX Developer is available as a one-part concentratein sizes to make one gallon and five gallons of workingsolution. You can easily mix smaller volumes by mixing onepart of the concentrate with four parts water. T-MAX RSDeveloper and Replenisher is available in convenient sizesto make one gallon and ten gallons of solution; use thissolution as a working-tank solution or a replenisher. Theten-gallon size consists of two separate units, each tomake five gallons of solution. 2017 Kodak Alaris Inc.KODAK PROFESSIONAL T-MAX RSDEVELOPER AND REPLENISHERFEATURESBENEFITS Mixed solution used as aworking-tank solution or areplenisher No need for a separatereplenisher solution No starter concentrate required Designed for processingsheets and rolls No need for separate developers Liquid concentrates Easy mixing Buffered solution Less affected by differences inwater supplies Ideal for large tanks andreplenished systems Excellent process uniformity Good shadow detail Good tone reproduction Excellent storagecharacteristics forconcentrate and workingsolution Long solution life Works well with normallyexposed film as well aspushed film One developer for normal andpush processing
REPLENISHMENTSTORAGEAdd 11 2 fluid ounces (45 mL) of solution for each 135-36or 120 roll or 8 x 10-inch sheet (or equivalent) processed.Stir or recirculate the solution thoroughly after eachaddition of replenisher solution.You can store working-strength solution in a full, tightlyclosed bottle for six months, in a half-filled bottle for twomonths, or in a covered tank for one month. You can storethe concentrate for up to two years.Note: Do not use KODAK T-MAX RS Developer andReplenisher to replenish KODAK T- MAX Developer.PROCESSINGPROCESS CONTROLUse KODAK Black-and-White Film Process Control Strips(CAT 180 2990) to monitor the developer activity ofT-MAX 1RS Developer and Replenisher. For moreinformation about using Black-and-White Film ProcessControl Strips, see the instructions packaged with thestrips.2The development times in the following tables are startingpoint recommendations. They are intended to produce acontrast index of 0.60 for KODAK PROFESSIONAL T-MAX400 Film and 0.56 for the other films. These developmenttimes should produce negatives with a contrast suitable forprinting with a diffusion enlarger. To adjust contrast forprinting with a condenser enlarger, reduce thedevelopment time by 20 to 30 percent.KODAK PROFESSIONAL T-MAX Developers J-86
MANUAL PROCESSINGSmall-Tank Processing(8- or 16-ounce tank)—RollsAgitate once every 30 seconds. Drop the loaded film reel into the developerand attach the top to the tank. Firmly tap the tank on the top of the work surfaceto dislodge any air bubbles. Provide initial agitation of 5 to 7 inversion cycles in5 seconds, i.e. extend your arm and vigorously twist your wrist 180 degrees asshown below.Then repeat this agitation procedure at 30-second intervals for the rest of the development time.KODAK T-MAX RS Developer and ReplenisherSpeed RatingKODAK FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400T-MAX P3200 ProfessionalPROFESSIONAL T-MAX P3200PLUS-X PanPLUS-X Pan ProfessionalPROFESSIONAL PLUS-X 125TRI-X PanTRI-X Pan ProfessionalPROFESSIONAL TRI-X 400 Film /400TXDevelopment Time (Minutes)EI18 C(65 F)20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)27 C(80 F)29 C(85 NR11 1 2——100/200NR871 276 1 4——1 4400———10——800————11 3 �1312119 1 2——512400*—8761 2651 2800—981 271 261 2651 21600—101 291 281 271 161412111025,000*—NRNR16141311400*—981 271 2761 251 2800—101 291 2981 271 261 281 271600—12111091 23200—141 2131211 1 21081 26400—16 1 21513 1 21311 1 21012,500*—181 217151 2141 2131125,000*—NRNR17161 2141 2121 2125/25061 251 241 2†4†31 2†——500NR981 271 26 1 2——1 4†125/250544†31 2†3†——500—7 1 461 265——400/8007651 251 25——91 21600—91 28——3200—12111 2111 211——32054†31 2†31 2†3†——400/80043 4†41 2†41 4†4†31 2†——160081 273 471 463 46——981 471 2——83200—91 2PROFESSIONAL TRI-X 320 Film /320TXP32041 2†4†31 2†31 4†23 4†——VERICHROME Pan125—4†4†31 2†31 2†——*Make tests to determine if results at these ratings are acceptable for your needs.†Development times shorter than 5 minutes may produce unsatisfactory uniformity.KODAK PROFESSIONAL T-MAX Developers J-86NR Not recommendedNote: The development times in bold type aresuggested starting points3
To agitate a sheet of film or a batch of sheet films in hangersin a tank, start the timer. Lower the hangers as a unit carefullyinto the developer. Tap the hangers sharply against the rim ofthe tank two or three times to dislodge air bubbles from thesurface of the film. (Air bubbles can interfere with developmentand produce low-density circles on the film.) Do not agitate thehangers for the remainder of the first minute. Lift all thehangers out of the solution and tilt them almost 90 degrees tothe left. Reimmerse the hangers, lift them out again, and thentilt them almost 90 degrees to the right. Do this as quickly andsmoothly as possible—in about 5 to 7 seconds. After youreimmerse the hangers, check their spacing. Repeat thisagitation cycle once every minute during the developmenttime.MANUAL PROCESSINGLarge-Tank Processing ( 2 to 3 2 -gallon tank)—Rolls11Agitating Rolls in a Large Tank: Agitate continuously for thefirst 15 to 30 seconds by raising and lowering the basket,rack, or spindle 1 cm (1 2 inch). Do not agitate the basket,rack, or spindle for the remainder of the first minute. Thenagitate once per minute by lifting the basket, rack, or spindleout of the developer, tilting it approximately 30 degrees,draining it for 5 to 10 seconds, and reimmersing it. Alternatethe direction of tilting the basket, rack, or spindle.Agitating Sheet Film in a Large Tank: Separate the sheetsby at least 1 cm (1 2 inch). Use a hanger loaded with an8 x 10-inch sheet of acetate or scrap film to avoid unevendevelopment or scratching of the larger sheets. (Thisunevenness is caused by turbulence around the centralframe of the multiple-film hanger during agitation.)Note: When you process films larger than 5 x 7 inches, becareful not to lift them from the solution so quickly that thefilms are pulled from the hangers.KODAK PROFESSIONAL T-MAX RS Developer and ReplenisherSpeed RatingKODAK FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400T-MAX 3200 ProfessionalPROFESSIONAL T-MAX P3200PLUS-X PanPLUS-X Pan ProfessionalPROFESSIONAL PLUS-X 125TRI-X PanTRI-X Pan ProfessionalPROFESSIONAL TRI-X 400 Film / 400TXDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)100/20010987 1 2400NRNRNR111 2100/20083 481 4400———11 1 4400/80081 2871 277160012111093200NRNRNR12400*101 291 281 271 2800111 210981600131 2111 2101 291 232001714 1 213126400NR18161412,500*NRNR1817400*1091 281 2880012101 21091 21600131 2121 2111 2101 23200161 2141 2131 2136400NR1715141 212,500*NRNR171 2161 2125/25087651 2500NRNRNR8125/25043 441 2431 2500NRNRNR53 4400/8001081 271 261 2101 29131 2160014121 23200NRNRNR320651 2400/800516008 3 41 2PROFESSIONAL TRI-X 320 Film / 320TXP3204VERICHROME Pan12551 2*Make tests to determine if results at these ratings are acceptable for your needs.†Development times shorter than 5 minutes may produce unsatisfactory uniformity.473 44451 253 44 1 2487 1 271 433 43 1 454†5NR Not recommendedNote: The development times in bold type are suggestedstarting pointsKODAK PROFESSIONAL T-MAX Developers J-86
MANUAL PROCESSINGLarge-Tank Processing (1 2 to 31 2-gallon tank)—SheetsKODAK PROFESSIONAL T-MAX RS Developer and ReplenisherSpeed RatingKODAK FilmT-MAX 100 ProfessionalDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)100/200121191 2873 476100/200T-MAX 400 Professional andPROFESSIONAL T-MAX 400400/8001087 1 2PLUS-X Pan Professional1259871 27TRI-X Pan Professional320541 2141 2141320/6403 1 231 4NRNR1005413 1 2131EKTAPAN1.Development81 4PROFESSIONAL T-MAX 100PROFESSIONAL TRI-X 320 Film /320TXP83 4times shorter than 5 minutes may produce unsatisfactory uniformity.NR Not recommendedNote: The development times in bold type are suggested starting points.Tray Processing—SheetsProvide continuous agitation; rotate the sheets 90 degrees as you interleave them.KODAK PROFESSIONAL T-MAX RS Developer and ReplenisherSpeed RatingKODAK PROFESSIONAL FilmDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)100/200111098PROFESSIONAL T-MAX 100100/2001 4T-MAX 400 Professional andPROFESSIONAL T-MAX 400400/800871 27PLUS-X Pan Professional125971 261 25TRI-X Pan Professional32054NRNR320/6402 3 42 1 2NRNR1005443T-MAX 100 ProfessionalPROFESSIONAL TRI-X 320 Film /320TXPEKTAPAN763 461 45 3 46NR Not recommendedNote: The development times in bold type are suggested starting points.KODAK PROFESSIONAL T-MAX Developers J-865
ROTARY-TUBE PROCESSINGRotary-Tube Processing—Rolls and SheetsFollow the agitation recommendations for your processor.KODAK T-MAX RS Developer and ReplenisherSpeed RatingKODAK Roll FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400T-MAX P3200 ProfessionalPROFESSIONAL T-MAX P3200PLUS-X PanPLUS-X Pan ProfessionalPROFESSIONAL PLUS-X 125TRI-X PanTRI-X Pan ProfessionalPROFESSIONAL TRI-X 400 Film /400TXPROFESSIONAL TRI-X 320 Film /320TXP1.MakeDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)27 C(80 F)29 C(85 F)100/200761 265——4001211108——800NRNR141 212——100/20073 471 463 46 1 4——400121 4111 2103 410——800NRNR12 3 411 3 4——400/80061 2651 25 1 2——160010981 28——32001413121 212——761 241 275951 240019871 280010987 1 21 2160012111032001513111 2101 2991 2764001614121 2111 210812,5001NR151413111 29 1 225,0001NR161514121 2114001981 271 2761 251 2800101 291 2981 271 261 2160012111091 281 273200141 21312111 21081 26400161 215131 213111 21012,5001181 217151 2141 2131117161 2141 2121 225,0001NRNR125/25041 241 244——5009871 27——125/25041 4431 23——50071 461 265——1 2031 2321 22——400/80041 241 4431 2——160073 47 1 46 3 46——320091 2981 471 2——32043 1 23 1 42 3 4——5tests to determine if results at these ratings are acceptable for your needs.NR Not recommendedNote: The development times in bold type are suggested starting points.6KODAK PROFESSIONAL T-MAX Developers J-86
KODAK T-MAX RS Developer and ReplenisherSpeed RatingKODAK Sheet FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400PLUS-X Pan ProfessionalPROFESSIONAL TRI-X 320 Film /320TXPDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)100/200761 2654001211108800NRNR141 212100/20073 471 46 3 46 1 4400121 4111 2103 410800NRNRNR11 3 4400/80061 2651 25 1 28160010981 232001413121 212125/25061 251 2541 2500101 2109832021 221 4NRNRNR Not recommendedNote: The development times in bold type are suggested starting points.KODAK PROFESSIONAL T-MAX Developers J-867
MACHINE PROCESSINGLarge-Tank Rack-and-Tank Processing—Rolls andSheetsThe development times for these processors are based ona machine speed that transfers the film every 2 minutes.The times given below are starting-pointrecommendations. Make tests to determine the bestdevelopment time for your application.Large-Tank Rack-and-Tank Processing—RollsKODAK T-MAX RS Developer and ReplenisherSpeed RatingKODAK FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400T-MAX 3200 ProfessionalPROFESSIONAL T-MAX P3200PLUS-X PanPLUS-X Pan ProfessionalDevelopmentTime(Minutes)122 C (72 F)6 to 8PROFESSIONAL T-MAX 100100/2006 to 8T-MAX 400 Professional andPROFESSIONAL T-MAX 400400/8006 to 8PLUS-X Pan Professional1256 to 8TRI-X Pan Professional3204 to 6320/6404 to 61004 to 612 to 254 to 6PROFESSIONAL TRI-X 320 Film /320TXP8 to 10Professional Copy / 41256 to 84008 to 10400/8006 to 816008 to 104002/8006 to 816008 to 10320010 to 12640012 to 1412,500214 to 164002/8006 to 816008 to 1032006 to 864008 to 1012,500210 to 12125/2504 to 66 to 8400/8006 to 816008 to 103206 to 8PROFESSIONAL TRI-X 400 Film/ 400TX400/8004 to 6PROFESSIONAL TRI-X 320 Film/ 320TXP320/6404 to 61256 to 8VERICHROME 06 to 8400SpeedRatingT-MAX 100 Professional100/20031 2 to 6TRI-X Pan ProfessionalKODAK Film22 C (72 F)500TRI-X PanKODAK T-MAX RS Developer and ReplenisherEI125/250PROFESSIONAL PLUS-X 125Large-Tank Rack-and-Tank Processing—Sheets1.Developmenttime depends on agitation and tank size.Note: Do not use T-MAX RS Developer and Replenisher inroller-transport processors. We recommend that you useKODAK DURAFLO RT Developer Starter, KODAKDURAFLO RT Developer Replenisher, and KODAK RapidFixer in roller-transport processors.1.Developmenttime depends on agitation and tank size.tests to determine if results at these ratings are acceptable for yourneeds.2.Make8KODAK PROFESSIONAL T-MAX Developers J-86
KODAK PROFESSIONAL T-MAX DEVELOPERFEATURESBENEFITS Liquid concentrates Easy mixing Concentrate mix ratio 1:4 Mix any amount you need Buffered solution Less affected by differences inwater supplies Good shadow detail Good tone reproduction Ideal for small tanks androtary-tube processors Excellent process uniformity Large capacity Process up to 48 rolls of film pergallon Excellent storagecharacteristics forconcentrate and workingsolution Long solution life Works well with normallyexposed film as well aspushed film One developer for normal andpush processingSTORAGEYou can store working-strength solution in a full, tightlyclosed bottle for six months, in half-filled bottle for twomonths, or in a covered tank for one month. You can storethe concentrate for up to two years.PROCESSINGThe development times in the following tables arestarting-point recommendations. They are intended toproduce a contrast index of 0.60 for T-MAX 400 Film and0.56 for the other films. These development times shouldproduce negatives with a contrast suitable for printing witha diffusion enlarger. To adjust contrast for printing with acondenser enlarger, reduce the development time by 20 to30 percent.CAPACITYThe capacity of this developer with normal processing isapproximately 48 rolls of 135-36 or 120 film per gallon (orequivalent), with time compensation. The capacity is lowerwhen you use the developer for push processing.Note: Do not use T-MAX RS Developer and Replenisher toreplenish T-MAX Developer.Time CompensationTo process the maximum number of rolls of film per gallonof T-MAX Developer, use time compensation according tothe table below. Discard the developer after you process48 rolls of film.If you use this developer for push processing, discard itafter processing one batch of film. The capacity of thesolution will be lower, and it should not be reused.Time CompensationKODAK PROFESSIONAL T-MAX DeveloperFilm Size136-36or1201.AtNumber of Rolls(per Gallon)DevelopmentTime Increase11 to 16Use normal developmenttime17 to 32Normal developmenttime 1 minute33 to 48Normal developmenttime 2 minutesthe primary recommended time and temperature.KODAK PROFESSIONAL T-MAX Developers J-869
MANUAL PROCESSINGSmall-Tank Processing(8- or 16-ounce tank)—RollsAgitate once every 30 seconds. Drop the loaded film reel into the developerand attach the top to the tank. Firmly tap the tank on the top of the worksurface to dislodge any air bubbles. Provide initial agitation of 5 to 7inversion cycles in 5 seconds, i.e. extend your arm and vigorously twist yourwrist 180 degrees as shown below.Then repeat this agitation procedure at 30-second intervals for the restof the development time.KODAK PROFESSIONAL T-MAX DeveloperSpeed RatingKODAK FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400T-MAX 3200 ProfessionalPROFESSIONAL T-MAX P3200PLUS-X PanPLUS-X Pan ProfessionalPROFESSIONAL PLUS-X 125TRI-X PanTRI-X Pan ProfessionalPROFESSIONAL TRI-X 400 Film /400TXDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)27 C(80 F)29 C(85 F)100/200871 276 1 2——4001211109——800NRNRNR101 2——100/20071 2761 21 4——400121 4——10——800———113 4——61 26——88——400/800716001061 2963200NRNRNR9 1 2——400*71 2761 2654†800871 2761 251 241 2†160081 2871 27653200111 211101 291 2861 26400141312119 1 28141 212,500*16151 225,000*NR171 21614121040081 2871 261 251 241 2†80091 2981 271 261 251 21600101 2109876320012111 2101 291 2861 2121 2101 296400131 2131211971 212,500151 2141 2131 2121081 225,000NR1615131 2111 291 2125/25051 251 255——500NRNRNR9——125/25053 451 443 4†41 4†——500NRNRNR6 1 4——1 2400/8006651 2——16001091 298 1 2——3200NRNRNR11——320871 276 1 2——400/80065 3 45 1 243 4†——1 43 4160083 487——3200NRNRNR8 1 4——PROFESSIONAL TRI-X 320 Film /320TXP3207 1 46 3 46 1 45 1 4——VERICHROME Pan12565 1 254†——*Make tests to determine if results at these ratings are acceptable for your needs.†Development times shorter than 5 minutes may produce unsatisfactory uniformity.1075NR Not recommendedNote: The development times in bold type are suggestedstarting pointsKODAK PROFESSIONAL T-MAX Developers J-86
ROTARY-TUBE PROCESSINGRotary-Tube Processing—RollsFollow the agitation recommendations for your processor.KODAK PROFESSIONAL T-MAX DeveloperSpeed RatingKODAK FilmT-MAX 100 ProfessionalPROFESSIONAL T-MAX 100T-MAX 400 Professional andPROFESSIONAL T-MAX 400T-MAX 3200 ProfessionalPROFESSIONAL T-MAX P3200PLUS-X PanPLUS-X Pan ProfessionalPROFESSIONAL PLUS-X 125TRI-X PanTRI-X Pan ProfessionalPROFESSIONAL TRI-X 400 Film /400TXPROFESSIONAL TRI-X 320 Film /320TXP1.MakeDevelopment Time (Minutes)EI20 C(68 F)21 C(70 F)22 C(72 F)24 C(75 F)27 C(80 F)29 C(85 F)100/20061 261 265 1 2——400101 21099——800NRNR1412 1 2——100/20073 471 463 46 1 4——400121 4111 2103 410——800NRNR123 411 3 4——400/80061 261 265 1 2——160081 2871 27——320011101 2109 1 2——400161 2651 241 231 2380071 261 265431 216008761 251 241 2432001191 281 271 2651 2640013111 2101 2971 261 212,5001141 21312101 29825,0001NR1514121110400*81 2871 261 251 241 280091 2981 271 261 251 21600101 2109876320012111 2101 291 2861 26400131 2131211971 212,500*151 2141 2131 2121081 21615131 2111 291 225,000*NR125/25051 2541 23 1 2——5009876——125/25053 451 443 44 1 4——50083 487 1 46 1 4——400/800651 254 1 2——16009871 26 1 2——32001211109——71 2320871 26——400/800653 451 243 4——160083 481 473 47——————3200NRNRNR81 432071 463 461 451 4tests to determine if results at these ratings are acceptable for your needs.NR Not recommendedNote: The development times in bold type are suggested starting points.KODAK PROFESSIONAL T-MAX Developers J-8611
QUICK REFERENCE TO PROCESSING FILMSBefore Processing Make sure all hangers and reels are clean and dry before loading film. Handle unprocessed panchromatic film in total darkness. Make sure all solution temperatures are close to the temperature of the developer (within ?1.7 C [?3 F]). Thetemperature recommendation for most developers is 20 C (68 F); for KODAK PROFESSIONAL T-MAX Developer, it is24 C (75 F).StepTimeAgitation and Notes1.DeveloperSee development tablesSmall tank (closed, cylindrical container that holds a single stack of spiralreels)—First tap the tank against the sink or counter to dislodge air bubblesthat cling to the film. Then agitate at a rate of about 4 inversion cycles(down, up) every 30 seconds (5 cycles in 5 seconds for T-MAX Films).Each inversion cycle should take about 1 second. If you cannot invert thetank without spilling the developer, slide it back and forth in about a 10-incharc for the same length of time.Large tank (open, rectangular container usually used for sheet film)—First,tap the hangers against the top of the tank to dislodge air bubbles. Then lift,tilt, and drain the hangers over the tank 2 times at 1-minute intervals. Tiltthe hangers to the right and then to the left to get even development.2.Stop Bath30 secondsAgitate continuously.3.FixerFix for twice as long as it takes the With a small tank, agitate continuously for the first 30 seconds and atfilm to clear (lose its milky30-second intervals after that. For a large tank, use 1-minute intervals.appearance); usually 2 to 4minutes in liquid-concentratefixers, 5 to 10 minutes in powderfixers4.Rinse30 secondsAgitate continuously for the first 30 seconds and then at 30-secondintervals.5.Hypo Clearing Agent1 to 2 minutesRinse the film in the tank under running water.6.Wash5 minutesRun the wash water fast enough to provide a complete change of water inthe container in 5 minutes. For rapid washing in a small tank, fill the tank tooverflowing with fresh water and then dump it all out. Repeat this cycle 10times.7.Wetting Agent30 secondsProvide gentle agitation for 5 seconds of the total time. To reduce dryingscum, mix KODAK PHOTO-FLO Solution with distilled water in areas thathave hard water.8.DryAs necessaryHang film in a clean, dust-free place.After ProcessingWash and dry all the equipmentthat came in contact withchemical solutions.When thoroughly dry, store negatives in sleeves or envelopes away fromdust and extreme temperature and humidly. For more information, seeStorage and Care of KODAK Photographic Materials—Before and AfterProcessing, Kodak Alaris Publication No. E-30.12KODAK PROFESSIONAL T-MAX Developers J-86
SIZES AVAILABLESizes and CAT numbers may differ from country to country.See your dealer who supplies KODAK PROFESSIONALProducts.KODAK PROFESSIONAL T-MAX RSDeveloper and ReplenisherCAT No.To make 1 gallon844 6163To make 10 gallons(2 units to make 5 gallons each)825 4237KODAK PROFESSIONAL T-MAX DeveloperCAT No.To make 1 gallon140 2767To make 5 gallons159 9844KODAK Black-and-White FilmProcess Control StripsCAT No.Box of 50 strips180 2990Note: The Kodak Alaris materials described in thispublication for use with KODAK PROFESSIONAL T-MAXDevelopers are available from dealers who supply KODAKPROFESSIONAL Products. You can use other materials,but you may not obtain similar results.MORE INFORMATIONKodak Alaris has many publications to assist you withinformation on Kodak Alaris products, equipment, andmaterials.The following publications are available from dealerswho sell Kodak Alaris products, or you can, emicals for KODAK PROFESSIONALBlack-and-White Films (Matrix)F-7KODAK VERICHROME Pan FilmF-8KODAK PLUS-X Pan and KODAK PLUS-X PanProfessional FilmsF-9KODAK TRI-X Pan and KODAK TRI-X Pan ProfessionalFilmsF-10KODAK EKTAPAN FilmF-16KODAK Professional Copy FilmF-32KODAK T-MAX Professional FilmsF-4016KODAK PROFESSIONAL T-MAX FilmsF-4017KODAK PROFESSIONAL TRI-X 320 Film / 320TXPF-4018KODAK PROFESSIONAL PLUS-X 125 FilmJ-87KODAK T-MAX 100 Direct Positive Film DevelopingOutfitThe following book is available from photo-specialty dealers whosell Kodak Alaris products:R-20KODAK Black-and-White DATAGUIDE 2017 Kodak Alaris Inc.TM/MC/MR: Duraflo, T-Max, VerichromeThe Kodak, Kodak Professional, Ektaflo, Ektapan, Plus-X, and Tri-X Trademarks are used under license from Eastman Kodak Company.KODAK PROFESSIONAL T-MAX DevelopersKODAK Publication No. J-86Revised 12-17KODAK ALARIS ROCHESTER, NY 14615
KODAK PROFESSIONAL T-MAX Developer is a moderately active, liquid black-and-white film developer that offers enhanced shadow detail in normally processed and push-processed films. The same description applies to KODAK PROFESSIONAL T-MAX RS Developer and Replenisher except that it is a black-and-white film developer and replenisher.