• Description: Location, as well as selection, of pipe supports is dependent upon the available s tructure to which the support may be attached. IV. PIPING SYSTEM SUPPORT DESIGN Pipe Data considered for design is: Pipe Size: DN 1000 Pipe Thickness: 6 mm Pipe Material: A358 TP 304 Max. Operating temperature: 100 0c Max. Operating Pressure: 0.28 bar.

  • Size: 225.51 KB

  • Type: PDF

  • Pages: 7

  • This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form.

    Report this link

Related Books:

DESIGN AND INSTALLATION GUIDE - Lysaght

DESIGN AND INSTALLATION GUIDE - Lysaght

Type of Span 0.60mm 0.80mm Roofs including bullnosed roofs Single span 1600 1800 End span 1600 1800 Internal span 1800 2600 Unstiffened eaves overhang 200 400 Stiffened eaves overhang 300 600 Walls Single span 2400 2400 End span 3000 3200 Internal span 3300 3600 Overhang 200 400 For roofs: the data are based on foot-traffic loading.

span tables

span tables

Span Tables for Case 1: Maximum Building Height = 4.8 m Single Span – Up to 600mm Overhang 100 x 50 mm ALYSPAN Beam Single Span – Max. 600 mm Overhang Max. Adjacent Building Height = 4.8 m W Maximum Allowable Span (mm) N1 N2 N3 N4 N5 1500 3300 3300 2800 2500 2200 1800 3100 2700 2300 2100 2100 3000 2600 2300 2000File Size: 1MB

Span guide for residential framing

Span guide for residential framing

Span For the purpose of using these tables, span may be interpreted as the clear distance between supports measured along the beam. Single Span Beams are beams supported at two points only. Continuous Span Beams are beams supported at three or more points along their length. Continuous span values given in the tables should only be used where:File Size: 494KB

Wood I Beam Joists

Wood I Beam Joists

(span/360) for a 30! span is 1" of deflection. L/240 would be 11⁄2," and L/180 would be 2" of deflection. Consideration might also be given to cases in which a joist with a long span parallels a short span or a foundation end wall. For example, a 30! span with up to 1" of allow-able live load deflection could be adjacent to an end wall with no

Monitoring Network Traffic Using SPAN

Monitoring Network Traffic Using SPAN

60-1 Cisco MDS 9000 Family Fabric Manager Configuration Guide OL-8007-10, Cisco MDS SAN-OS Release 3.x 60 Monitoring Network Traffic Using SPAN This chapter describes the Switched Port Analyzer (SPAN) features provided in switches in the Cisco MDS 9000 Family. It includes the following sections: • About SPAN, page 60-2 • SPAN Sources, page 60-2

COLORB EAM FLAT ROOF SPAN TABLES

COLORB EAM FLAT ROOF SPAN TABLES

CB150-16 Beam span table used W = 3600 (Width of Frame / Rafter span) χ = 6410 (Fascia Beam span) The CB150-16 beam achieves the 6000mm span for the fascia beam and can be used for the rafters. Rafters can be omitted as they are not structural in the application. W Awning frame width. The

DOMESTIC DECK DESIGN GUIDE - TasmanKB

DOMESTIC DECK DESIGN GUIDE - TasmanKB

SPAN CAPACITY Various ti mber decking boards have diff erent span capacity. Table 2 gives maximum span of the common decking board ti mbers and thicknesses. Table 2 Maximum joist spacing for various decking boards Decking Stress Grade Thickness (mm) Maximum joist spacing (mm) Hardwood Stand

DR4500A Classic Series Circular Chart Recorder . - Honeywell

DR4500A Classic Series Circular Chart Recorder . - Honeywell

44-45-03-15 Page 4 Specifications Design Digital Indication Accuracy 1 digit Minimum Input Span Range is fully configurable with span limitation of the operating range selected. Input Impedance 4-20 mAdc: 250 ohms 0-10 Vdc: 200K ohms All others: 10 Megohms Source Impedance RTD: 100 ohms per lead maximum Span Step Response Time 6-seconds maximum with no filtering

Configuring SPAN and RSPAN

Configuring SPAN and RSPAN

† SPAN Traffic, page 60-6 SPAN Session A local SPAN session associates a destination port with source ports. You can monitor incoming or outgoing traffic on a series or range of ports and source VLANs. An RSPAN session associates source ports and source VLANs across your network with an RSPAN VLAN. The destination source is the

STRUCTURAL ANALYSIS –II

STRUCTURAL ANALYSIS –II

Span AB: Max BM in span AB occurs under point load and can be found geometrically, M. max =113.33-51.38 – Span BC: Max BM in span BC occurs where shear force is zero or changes its sign. Hence consider SF equation w.r.t C S. x = 35-20x = 0 =1.75m Max …

BOXSPAN RESIDENTIAL SPAN TABLES

BOXSPAN RESIDENTIAL SPAN TABLES

2019 Spantec Sstems Pt Lt. BOXSPAN ® Resenta Span Taes. Ap 2019 Definitions & Terminology SPANS The tables in this publication refer to three types of spans. See diagram on the right. For a member to be in continuous span the smallest span must be greater than 80% of the other

The Span Book - CWC

The Span Book - CWC

The Span Book is a supplement to the wood joist, rafter and beam spans found in the National Building Code of Canada. Tables in the Span Book and the National Building Code were both generated by the Canadian Wood Council. The National Building Code references the Span Book as fol