• Description: Heat capacity at constant pressure in kJ/(kg)( C) C v Heat capacity at constant volume in kJ/(kg)( C) v s Velocity of sound in m/sec The gas constant, R 8.314 J/(mole) (K) for Freon 410A, R 0.11455 kJ/kg·K One atmosphere 101.325 kPa Reference point for enthalpy and entropy: h f 200 kJ/kg at 0 C s f 1 kJ/kg·K at 0 C ..

  • Size: 558.54 KB

  • Type: PDF

  • Pages: 28

  • This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form.

    Report this link

Related Books:

Refrigerants (R-407C and R-410A) Properties, Uses, Storage, and . - Freon

Refrigerants (R-407C and R-410A) Properties, Uses, Storage, and . - Freon

The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the

Refrigerant (R-134a) Properties, Uses, Storage, and Handling

Refrigerant (R-134a) Properties, Uses, Storage, and Handling

Oil Mineral Oil Mineral Oil UCON RO-W-6602* Mobil EAL Arctic 32** Castrol Icematic SW 100** Oil Viscosity, cSt at 40 °C (104 °F) 30.7 125 134 29.4 108.8 Refrigerant R-12 R-12 Freon™ 134a Freon™ 134a Freon™ 134a Ratings Neat

R-410A - Refrigerants

R-410A - Refrigerants

R-410A Safety Data Sheet R-410A 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: R-410A OTHER NAME: Difluoromethane, Pentafluoroethane USE: Refrigerant Gas DISTRIBUTOR: National Refrigerants, Inc. 661 Kenyon Avenue Bridgeton, New Jersey 08302

TECHNICAL SUPPORT MANUAL Two--Stage Split System Heat Pump (H,C,T)CH6

TECHNICAL SUPPORT MANUAL Two--Stage Split System Heat Pump (H,C,T)CH6

TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)CH(6) 4 428 04 170100 R--410A QUICK REFERENCE GUIDE •R--410A refrigerant operates at 50% -- 70% higher pressures than R--22. Be sure that servicing equipment and replacement components are designed to operate with R--410A.

INSTALLATION INSTRUCTIONS RGS089-180 R-410A Single Package . - HVACDirect

INSTALLATION INSTRUCTIONS RGS089-180 R-410A Single Package . - HVACDirect

on unit, always turn off main power switch to unit and install lock(s) and lockout tag(s). Unit may have more than one power switch. WARNING Failure to follow this warning could cause personal injury, death and/or equipment damage. R-410A refrigerant systems operate at higher pressures than standard R-22 systems. Do not use R-410A service equip-

Ashrae 90.1 Compliant

Ashrae 90.1 Compliant

Refrigerant Type R-410A R-410A R-410A Charge Furnished 5 lbs. 2 oz. 5 lbs. 4 oz. 7 lbs. 5 oz. Gas Heating Options - See page 14 Standard (1 Stage) or Medium (1 Stage) Standard (1 Stage) or Medium (1 Stage) Medium (2 Stage) or High (2 Stage) Compressor Type (one per unit) Scroll Scroll Scroll Outdoor Coil Net face area - sq. ft. 15.2 15.2 19.9

Technical Information - Chemours

Technical Information - Chemours

Viton™ during injection, compression, or transfer molding or extrusion (see Appendix 1). Suggested maximum use limits are 2 phr for VC-1 and 4 phr for VC-3. Note: Additional information on Viton™ curing agents is contained in Chemours bulletin, "Viton™ Curing Agents for Viton™ Fluoroelastomers." Viton™ Curative No. 4 (VC-4) is

Parallel Computing on SoC Architecture

Parallel Computing on SoC Architecture

Once upon a time.... Serial number 001 Cray-1™ Los Alamos National Laboratory in 1976 $8.8 million 80 MFLOPS scalar, 160/250 MFLOPS vector 1 Mword (64 bit) main memory 8 vector registers 64 elements 64bit each Freon refrigerated 5.5 tons including the Freon refrigeration 115 kW of power 330 kW with refrigeration

CKL, CLJ, CRT, CLT, TWC, CLQ & HDC Split . - HVACPartsShop

CKL, CLJ, CRT, CLT, TWC, CLQ & HDC Split . - HVACPartsShop

• Never add anything other than R-22 to an R-22 cylinder or R-410A to an R-410A cylinder. The service equipment used must be listed or certified for the type of refrigerant used. • Store cylinders in a cool, dry place. Never use a cylinder as a platform or a roller. WARN

SERVICE MANUAL R 410A Ductless Split System Air .

SERVICE MANUAL R 410A Ductless Split System Air .

421 01 9204 00 1/03/13 SERVICE MANUAL R−410A Ductless Split System Air Conditioner and Heat Pump MODELS: DLC4(A/H)−Outdoor, DLF4(A/H)−Indoor SIZES: 9K, 12K, 18K, 24K, 30K, and 36K INTRODUCTION